Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
36th IEEE International Conference on Micro Electro Mechanical Systems, MEMS 2023 ; 2023-January:433-436, 2023.
Article in English | Scopus | ID: covidwho-2273127

ABSTRACT

We have designed, fabricated, and tested a MEMS-based impedance biosensor for accurate and rapid detection of severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) using of clinical samples. The device consists of focusing region that concentrate low quantities of the virus present in the samples to a detectable threshold, trap region hat maximize the captured virus, and detection region to detect the virus with high selectivity and sensitivity, using an array of interdigitated electrodes (IDE) coated with a specific antibody. Changes in the impedance value due to the binding of the SARS-COV-2 antigen to the antibody will indicate positive or negative result. The device was able to detect inactivated SARS-COV-2 antigen present in phosphate buffer saline (PBS) with a concentration as low as 50 TCID50/ml in 30 minutes. In addition, the biosensor was able to detect SARS-COV-2 in clinical samples (swabs) with a sensitivity of 84 TCID50/ml, also in 30 minutes. © 2023 IEEE.

2.
Biosensors and Bioelectronics: X ; 13, 2023.
Article in English | Scopus | ID: covidwho-2246569

ABSTRACT

This paper presents a portable, fast and accurate electrochemical impedance spectroscopy (EIS) device with 8-well interdigitated electrode chips for biomarker detection. The design adopts low crest factor multisine signal synthesis at low frequencies (<1 kHz) and single-tone signals at high frequencies (>1 kHz), which significantly increases measurement speed without sacrificing accuracy. In addition, the low excitation amplitude of 10 mV preserves impedance linearity and protects the biosamples. The system achieved an average magnitude accuracy error of 0.30% in the frequency range of interest and it requires only 0.46 s to scan 28 frequency points from 10 Hz to 1 MHz. Experiments were conducted to test the capability to detect antibodies against SARS-CoV-2. Gold nanoparticles bound with protein G (GNP-G) were employed as the conjugated secondary antibody probe to detect anti-SARS-CoV-2 IgG in serum. A highly statistical significance (p = 7×10−6) could be found in the impedance data at 10 kHz. The impedance magnitude alteration caused by the GNP-G of the positive and negative groups were 27.2%±13.6% and 4.1%±1.7%, respectively. The results imply that the proposed system enables rapid COVID-19 antibody biomarker detection. Moreover, the EIS system and GNPs have the potential to be modified to detect other biomarkers. © 2022 The Author(s)

SELECTION OF CITATIONS
SEARCH DETAIL